Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 20 de 42
Filter
1.
Sensors (Basel) ; 23(8)2023 Apr 21.
Article in English | MEDLINE | ID: covidwho-2321695

ABSTRACT

This paper reports the architecture of a low-cost smart crutches system for mobile health applications. The prototype is based on a set of sensorized crutches connected to a custom Android application. Crutches were instrumented with a 6-axis inertial measurement unit, a uniaxial load cell, WiFi connectivity, and a microcontroller for data collection and processing. Crutch orientation and applied force were calibrated with a motion capture system and a force platform. Data are processed and visualized in real-time on the Android smartphone and are stored on the local memory for further offline analysis. The prototype's architecture is reported along with the post-calibration accuracy for estimating crutch orientation (5° RMSE in dynamic conditions) and applied force (10 N RMSE). The system is a mobile-health platform enabling the design and development of real-time biofeedback applications and continuity of care scenarios, such as telemonitoring and telerehabilitation.


Subject(s)
Mobile Applications , Telemedicine , Humans , Biomechanical Phenomena , Smartphone , Continuity of Patient Care , Gait
2.
Med Sci Sports Exerc ; 55(8): 1366-1374, 2023 Aug 01.
Article in English | MEDLINE | ID: covidwho-2253040

ABSTRACT

PURPOSE: This study assessed the effects of the COVID-19 pandemic restrictions/lockdowns on physical activity levels, body mass, quadriceps strength, and gait biomechanics over 18 months. METHODS: Ten healthy men were assessed at baseline (~14 wk before first lockdown) and 17.9 ± 0.3 months later (<1 wk after second lockdown). At both times, physical activity levels, body mass, and quadriceps strength were acquired using the International Physical Activity Questionnaire, a force plate, and a dynamometer, respectively. Gait data were also acquired using a motion capture system and force plates during self-paced walking, from which spatiotemporal parameters, knee angles, and external moments were computed. Baseline and follow-up measurements were compared using two-tailed paired t -tests ( α = 0.05). RESULTS: At follow-up, participants spent less time doing vigorous physical activity (∆ = -76 ± 157 min·wk -1 , P = 0.048), exhibited a tendency toward increased sedentary time (∆ = +120 ± 162 min·d -1 , P = 0.056), weighed more (∆ = +2.5 ± 2.8 kg, P = 0.021), and showed a trend toward reduced quadriceps strength (∆ = -0.29 ± 0.45 (N·m)·kg -1 , P = 0.071) compared with baseline. At follow-up, participants walked slower (∆ = -0.09 ± 0.07 m·s -1 , P = 0.005), had greater knee flexion angles at heel strike (∆ = +2.2° ± 1.8°, P = 0.004) and during late stance (∆ = +2.2° ± 1.8°, P = 0.004), had reduced knee extension moments (∆ = -0.09 ± 0.09 (N·m)·kg -1 , P = 0.012) and knee internal rotation moments (∆ = -0.02 ± 0.02 (N·m)·kg -1 , P = 0.012) during late stance. CONCLUSIONS: Healthy men exhibited reduced physical activity levels, increased body weight, a tendency toward reduced quadriceps strength, and altered gait biomechanics over the initial 18 months of the COVID-19 pandemic-alterations that could have far-reaching health consequences.


Subject(s)
COVID-19 , Pandemics , Male , Humans , Biomechanical Phenomena , Muscle Strength , Communicable Disease Control , Gait , Knee Joint , Walking , Quadriceps Muscle , Body Weight
3.
J Biomech ; 146: 111419, 2023 01.
Article in English | MEDLINE | ID: covidwho-2159185

ABSTRACT

Gender biases and inequities are prevalent across many scientific fields and biomechanics is likely no exception. While progress has been made to support women in the field, especially at biomechanics society conferences, the recent COVID-19 pandemic has exacerbated professional isolation. The International Women in Biomechanics (IWB) community started in July 2020 with the mission of fostering an environment for women and other under-represented genders in biomechanics to gain year-round support, visibility, and allyship. Nearly 700 biomechanists have joined the IWB community from over 300 universities/organizations and 33 countries. Our community ranges in career stages and professions and interacts through a forum-style platform, teleconference meetings, and social media. In 2021, we conducted a survey to identify the needs, concerns, and issues faced by individuals in the IWB community. We received 144 responses from members in 16 countries. Our survey revealed three primary needs for women in biomechanics: supportive working environments, career planning support, and addressing workplace gender bias. These results, in conjunction with scientific evidence on workforce gender bias, helped us identify three key areas to meet our mission: Member Support, Community Outreach, and Empowering Allyship. Several levels of support are required in these three areas to ensure a lasting, positive, and sustainable impact on gender equity in biomechanics. We conclude by providing our perspectives on an evidence-based call to action to continue addressing gender bias and inequity at the individual, institutional, and scientific society levels. These actions can collectively enhance our allyship for women in the field of biomechanics.


Subject(s)
COVID-19 , Sexism , Humans , Female , Male , Biomechanical Phenomena , Pandemics
4.
Sensors (Basel) ; 22(16)2022 Aug 13.
Article in English | MEDLINE | ID: covidwho-2024040

ABSTRACT

As obesity is a serious problem in the human population, overloading of the horse's thoracolumbar region often affects sport and school horses. The advances in using infrared thermography (IRT) to assess the horse's back overload will shortly integrate the IRT-based rider-horse fit into everyday equine practice. This study aimed to evaluate the applicability of entropy measures to select the most informative measures and color components, and the accuracy of rider:horse bodyweight ratio detection. Twelve horses were ridden by each of the six riders assigned to the light, moderate, and heavy groups. Thermal images were taken pre- and post-exercise. For each thermal image, two-dimensional sample (SampEn), fuzzy (FuzzEn), permutation (PermEn), dispersion (DispEn), and distribution (DistEn) entropies were measured in the withers and the thoracic spine areas. Among 40 returned measures, 30 entropy measures were exercise-dependent, whereas 8 entropy measures were bodyweight ratio-dependent. Moreover, three entropy measures demonstrated similarities to entropy-related gray level co-occurrence matrix (GLCM) texture features, confirming the higher irregularity and complexity of thermal image texture when horses worked under heavy riders. An application of DispEn to red color components enables identification of the light and heavy rider groups with higher accuracy than the previously used entropy-related GLCM texture features.


Subject(s)
Sports , Thermography , Animals , Back , Biomechanical Phenomena , Body Weight , Entropy , Horses , Humans
5.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 1814-1817, 2022 07.
Article in English | MEDLINE | ID: covidwho-2018738

ABSTRACT

Open-access databases can facilitate data sharing among researchers and provide normative data for objective clinical assessment development, robotic design, and biomechanical modeling. However, most existing databases focus on gait, balance, and hand gestures without providing elbow and shoulder kinematics that are required in activities of daily living. Furthermore, the few existing upper limb datasets include small sample sizes without consistent data collection protocols, which hinder robotic engineers' ability to design robotic devices that accommodate the general population. To address the literature gap, an open-access upper limb kinematic database was proposed. Due to the impact of COVID-19 on human research, only data from 16 participants were collected. Clinical Relevance-This provides baseline kinematics for developing objective clinical assessments and rehabilitation robots.


Subject(s)
COVID-19 , Robotics , Activities of Daily Living , Biomechanical Phenomena , Humans , Robotics/methods , Upper Extremity
6.
Biomech Model Mechanobiol ; 21(6): 1685-1702, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2007165

ABSTRACT

Mechanical characterisation of the layer-specific, viscoelastic properties of the human oesophagus is crucial in furthering the development of devices emerging in the field, such as robotic endoscopic biopsy devices, as well as in enhancing the realism, and therefore effectiveness, of surgical simulations. In this study, the viscoelastic and stress-softening behaviour of the passive human oesophagus was investigated through ex vivo cyclic mechanical tests. Due to restrictions placed on the laboratory as a result of COVID-19, only oesophagi from cadavers fixed in formalin were allowed for testing. Three oesophagi in total were separated into their two main layers and the mucosa-submucosa layer was investigated. A series of uniaxial tensile tests were conducted in the form of increasing stretch level cyclic tests at two different strain rates: 1% s[Formula: see text] and 10% s[Formula: see text]. Rectangular samples in both the longitudinal and circumferential directions were tested to observe any anisotropy. Histological analysis was also performed through a variety of staining methods. Overall, the longitudinal direction was found to be much stiffer than the circumferential direction. Stress-softening was observed in both directions, as well as permanent set and hysteresis. Strain rate-dependent behaviour was also apparent in the two directions, with an increase in strain rate resulting in an increase in stiffness. This strain rate dependency was more pronounced in the longitudinal direction than the circumferential direction. Finally, the results were discussed in regard to the histological content of the layer, and the behaviour was modelled and validated using a visco-hyperelastic matrix-fibre model.


Subject(s)
COVID-19 , Humans , Anisotropy , Stress, Mechanical , Esophagus , Mucous Membrane , Biomechanical Phenomena
7.
Eur J Appl Physiol ; 122(12): 2565-2574, 2022 Dec.
Article in English | MEDLINE | ID: covidwho-2007145

ABSTRACT

PURPOSE: With few cycling races on the calendar in 2020 due to COVID-19, Everesting became a popular challenge: you select one hill and cycle up and down it until you reach the accumulated elevation of Mt. Everest (8,848 m or 29,029ft). With an almost infinite number of different hills across the world, the question arises what the optimal hill for Everesting would be. Here, we address the biomechanics and energetics of up- and downhill cycling to determine the characteristics of this optimal hill. METHODS: During uphill cycling, the mechanical power output equals the power necessary to overcome air resistance, rolling resistance, and work against gravity, and for a fast Everesting time, one should maximize this latter term. To determine the optimal section length (i.e., number of repetitions), we applied the critical power concept and assumed that the U-turn associated with an additional repetition comes with a 6 s time penalty. RESULTS: To use most mechanical power to overcoming gravity, slopes of at least 12% are most suitable, especially since gross efficiency seems only minimally diminished on steeper slopes. Next, we found 24 repetitions to be optimal, yet this number slightly depends on the assumptions made. Finally, we discuss other factors (fueling, altitude, fatigue) not incorporated in the model but also affecting Everesting performances. CONCLUSION: For a fast Everesting time, our model suggests to select a hill climb which preferably starts at (or close to) sea level, with a slope of 12-20% and length of 2-3 km.


Subject(s)
COVID-19 , Humans , Bicycling , Biomechanical Phenomena , Altitude , Gravitation
8.
PLoS One ; 17(8): e0273308, 2022.
Article in English | MEDLINE | ID: covidwho-2002324

ABSTRACT

INTRODUCTION: The use of portable gait measurement systems in research is appealing to collect real-world data at low-cost, low participant burden, and without requirement for dedicated lab space. Most commercially available inertial measurement units (IMU's) designed for running only capture temporospatial data, the ability to capture biomechanics data such as shock and motion metrics with the RunScribe IMU makes it the closest to a lab alternative. The RunScribe system has been validated in running, however, is yet to be validated for walking. METHOD: Qualisys motion capture, AMTI force plates, and Delsys Trigno accelerometers were used as gold standard lab measures for comparison against the RunScribe IMU. Twenty participants completed 10 footsteps per foot (20 total) measured by both systems simultaneously. Variables for validation included: Vertical Ground reaction force (GRF), instantaneous GRF rate, pronation excursion, pronation velocity, total shock, impact force, braking force. Interclass correlation (ICC) was used to determine agreement between the measurement systems, mean differences were used to evaluate group level accuracy. RESULTS: ICC results showed moderate agreement between measurement systems when both limbs were averaged. The greatest agreement was seen for GRF rate, pronation excursion, and pronation velocity (ICC = 0.627, 0.616, 0.539), low agreement was seen for GRF, total shock, impact shock, braking shock (ICC = 0.269, 0.351, 0.244, 0.180). However mean differences show the greatest level of accuracy for GRF, GRF rate, and impact shock. DISCUSSION: Results show mixed agreement between the RunScribe and gold standard lab measures, and varied agreement across left and right limbs. Kinematic variables showed the greatest agreement, however GRF had the lowest relative mean difference for group results. The results show acceptable levels of agreement for most variables, however further work must be done to assess the repeatability and sensitivity of the RunScribe to be applied within areas such as footwear testing and gait retraining protocols.


Subject(s)
Gait , Running , Biomechanical Phenomena , Foot , Humans , Walking
9.
Sensors (Basel) ; 22(15)2022 Aug 07.
Article in English | MEDLINE | ID: covidwho-1979350

ABSTRACT

A mask is one of the most basic protections to prevent the transmission of COVID-19. Surgical mask tension release bands (SMTRBs) are commonly used to ease the pain caused by prolonged mask use. However, the structural strength of SMTRBs and the effect that wearing masks with SMTRBs has on the face are unclear. Thus, this study assessed the mechanics of seven different types of 3D-printed SMTRBs. In this study, a tensile testing machine, a sensor array system, and finite element analysis were used to evaluate the mechanisms of seven SMTRBs. The tensile testing machine was applied to measure the breaking strength, elongation, stiffness, and rupture of the band. The sensor array system was used to calculate the pressure on the face when the band was used together with the mask. Finite element analysis was applied to evaluate the level of stress on the SMTRB structure when each of the seven bands was subjected to external force. The results demonstrated that thick SMTRBs put more pressure on the face but had greater structural strength. The thinner bands did not break easily; however, the mask ear loops tended to slip off more often. In addition, the size of the band hook affected the magnitude of the external force. This study provides a biomechanical reference for the future design of SMTRBs.


Subject(s)
COVID-19 , Masks , Biomechanical Phenomena , Finite Element Analysis , Humans , Printing, Three-Dimensional
10.
Sensors (Basel) ; 22(13)2022 Jun 30.
Article in English | MEDLINE | ID: covidwho-1934199

ABSTRACT

Wheelchair users must use proper technique when performing sitting-pivot-transfers (SPTs) to prevent upper extremity pain and discomfort. Current methods to analyze the quality of SPTs include the TransKinect, a combination of machine learning (ML) models, and the Transfer Assessment Instrument (TAI), to automatically score the quality of a transfer using Microsoft Kinect V2. With the discontinuation of the V2, there is a necessity to determine the compatibility of other commercial sensors. The Intel RealSense D435 and the Microsoft Kinect Azure were compared against the V2 for inter- and intra-sensor reliability. A secondary analysis with the Azure was also performed to analyze its performance with the existing ML models used to predict transfer quality. The intra- and inter-sensor reliability was higher for the Azure and V2 (n = 7; ICC = 0.63 to 0.92) than the RealSense and V2 (n = 30; ICC = 0.13 to 0.7) for four key features. Additionally, the V2 and the Azure both showed high agreement with each other on the ML outcomes but not against a ground truth. Therefore, the ML models may need to be retrained ideally with the Azure, as it was found to be a more reliable and robust sensor for tracking wheelchair transfers in comparison to the V2.


Subject(s)
Wheelchairs , Arm , Biomechanical Phenomena , Motion , Reproducibility of Results
11.
J Chem Inf Model ; 62(11): 2869-2879, 2022 06 13.
Article in English | MEDLINE | ID: covidwho-1860271

ABSTRACT

The three-dimensional conformations of a protein influence its function and select for the ligands it can interact with. The total free energy change during protein-ligand complex formation includes enthalphic and entropic components, which together report on the binding affinity and conformational states of the complex. However, determining the entropic contribution is computationally burdensome. Here, we apply kinematic flexibility analysis (KFA) to efficiently estimate vibrational frequencies from static protein and protein-ligand structures. The vibrational frequencies, in turn, determine the vibrational entropies of the structures and their complexes. Our estimates of the vibrational entropy change caused by ligand binding compare favorably to values obtained from a dynamic Normal Mode Analysis (NMA). Higher correlation factors can be achieved by increasing the distance cutoff in the potential energy model. Furthermore, we apply our new method to analyze the entropy changes of the SARS CoV-2 main protease when binding with different ligand inhibitors, which is relevant for the design of potential drugs.


Subject(s)
COVID-19 , Severe Acute Respiratory Syndrome , Biomechanical Phenomena , Entropy , Humans , Ligands , Protein Binding , Proteins/chemistry
12.
Biomech Model Mechanobiol ; 21(4): 1169-1186, 2022 Aug.
Article in English | MEDLINE | ID: covidwho-1813697

ABSTRACT

The oesophagus is a primarily mechanical organ whose material characterisation would aid in the investigation of its pathophysiology, help in the field of tissue engineering, and improve surgical simulations and the design of medical devices. However, the layer-dependent, anisotropic properties of the organ have not been investigated using human tissue, particularly in regard to its viscoelastic and stress-softening behaviour. Restrictions caused by the COVID-19 pandemic meant that fresh human tissue was not available for dissection. Therefore, in this study, the layer-specific material properties of the human oesophagus were investigated through ex vivo experimentation of the embalmed muscularis propria layer. For this, a series of uniaxial tension cyclic tests with increasing stretch levels were conducted at two different strain rates. The muscular layers from three different cadaveric specimens were tested in both the longitudinal and circumferential directions. The results displayed highly nonlinear and anisotropic behaviour, with both time- and history-dependent stress-softening. The longitudinal direction was found to be stiffer than the circumferential direction at both strain rates. Strain rate-dependent behaviour was apparent, with an increase in strain rate resulting in an increase in stiffness in both directions. Histological analysis was carried out via various staining methods; the results of which were discussed with regard to the experimentally observed stress-stretch response. Finally, the behaviour of the muscularis propria was simulated using a matrix-fibre model able to capture the various mechanical phenomena exhibited, the fibre orientation of which was driven by the histological findings of the study.


Subject(s)
COVID-19 , Pandemics , Anisotropy , Biomechanical Phenomena , Esophagus , Humans , Stress, Mechanical
13.
J Arthroplasty ; 37(6S): S350-S354, 2022 06.
Article in English | MEDLINE | ID: covidwho-1748218

ABSTRACT

BACKGROUND: Since the COVID-19 pandemic of 2020, there has been a marked rise in the use of telemedicine to evaluate patients after total knee arthroplasty (TKA). The purpose of our study was to assess a novel stem with an embedded sensor that can remotely and objectively monitor a patient's mobility after TKA. METHODS: A single anatomically designed knee system was implanted in concert with an interconnected tibial stem extension containing 3D accelerometers, 3D gyroscopes, a power source, and a telemetry transmission capability in 3 cadaveric pelvis to toe specimens. The legs were moved by hand to preset tibial positions at full knee extension, midflexion, flexion, and back to midflexion and extension for a total of 16 trials across 6 knees. RESULTS: Sensor data were successfully transmitted with good quality of signal to an external base station. Good correlation to the range of motion of the tibia was found (mean error 0.1 degrees; root mean square error 3.8 degrees). The signal from the heel drop tests suggests the sensor could detect heel strike during activities of daily living in vivo and the potential for additional signal processing to analyze vibratory and motion patterns detected by the sensors. A frequency domain analysis of a properly cemented and poorly cemented implant during the heel drop test suggests a difference in accelerometer signal in these implant states. CONCLUSION: The results confirm signals generated from an embedded TKA sensor can transmit through bone and cement, providing accurate range of motion data and may be capable of detecting changes in prosthesis fixation remotely.


Subject(s)
Arthroplasty, Replacement, Knee , COVID-19 , Knee Prosthesis , Activities of Daily Living , Arthroplasty, Replacement, Knee/adverse effects , Biomechanical Phenomena , COVID-19/prevention & control , Cadaver , Feasibility Studies , Humans , Knee Joint/surgery , Monitoring, Physiologic , Pandemics , Range of Motion, Articular , Tibia/surgery
14.
Sensors (Basel) ; 22(3)2022 Jan 22.
Article in English | MEDLINE | ID: covidwho-1686938

ABSTRACT

One of the causes of positioning inaccuracies in the Unmanned Aircraft System (UAS) is navigation error. In urban environment operations, multipaths could be the dominant contributor to navigation errors. This paper presents a study on how the operation environment affects the lateral (horizontal) navigation performance when a self-built UAS is going near different types of urban obstructions in real flight tests. Selected test sites are representative of urban environments, including open carparks, flight paths obstructed by buildings along one or both sides, changing sky access when flying towards corners formed by two buildings or dead ends, and buildings with reflective glass-clad surfaces. The data was analysed to obtain the horizontal position error between Global Positioning System (GPS) position and ground truth derived from Real Time Kinematics (RTK), with considerations for (1) horizontal position uncertainty estimate (EPH) reported by the GPS receiver, (2) no. of visible satellites, and (3) percentage of sky visible (or sky openness ratio, SOR) at various altitudes along the flight paths inside the aforementioned urban environments. The investigation showed that there is no direct correlation between the measured horizontal position error and the reported EPH; thus, the EPH could not be used for the purpose of monitoring navigation performance. The investigation further concluded that there is no universal correlation between the sky openness ratio (SOR) seen by the UAS and the resulting horizontal position error, and a more complex model would need to be considered to translate 3D urban models to expected horizontal navigation uncertainty for the UAS Traffic Management (UTM) airspace.


Subject(s)
Aircraft , Geographic Information Systems , Biomechanical Phenomena
15.
Int J Environ Res Public Health ; 19(3)2022 01 25.
Article in English | MEDLINE | ID: covidwho-1686729

ABSTRACT

The introduction of carbon fiber plate shoes has triggered a plethora of world records in running, which has encouraged shoe industries to produce novel shoe designs to enhance running performance, including shoes containing conductor elements or "grounding shoes" (GS), which could potentially reduce the energy cost of running. The aim of this study was to examine the physiological and perceptual responses of athletes subjected to grounding shoes during running. Ten elite runners were recruited. Firstly, the athletes performed an incremental running test for VO2max and anaerobic threshold (AT) determination, and were familiarized with the two shoe conditions (traditional training shoe (TTS) and GS, the latter containing a conductor element under the insole). One week apart, athletes performed running economy tests (20 min run at 80% of the AT) on a 400 m dirt track, with shoe conditions randomized. VO2, heart rate, lactate, and perceived fatigue were registered throughout the experiment. No differences in any of the physiological or perceptual variables were identified between shoe conditions, with an equal running economy in both TTS and GS (51.1 ± 4.2 vs. 50.9 ± 5.1 mL kg-1 min-1, respectively). Our results suggest that a grounding stimulus does not improve the energy cost of running, or the physiological/perceptual responses of elite athletes.


Subject(s)
Running , Shoes , Athletes , Biomechanical Phenomena , Humans , Lactic Acid , Running/physiology
16.
BMC Pulm Med ; 22(1): 51, 2022 Feb 04.
Article in English | MEDLINE | ID: covidwho-1666648

ABSTRACT

BACKGROUND: Understanding heterogeneity seen in patients with COVIDARDS and comparing to non-COVIDARDS may inform tailored treatments. METHODS: A multidisciplinary team of frontline clinicians and data scientists worked to create the Northwell COVIDARDS dataset (NorthCARDS) leveraging over 11,542 COVID-19 hospital admissions. The data was then summarized to examine descriptive differences based on clinically meaningful categories of lung compliance, and to examine trends in oxygenation. FINDINGS: Of the 1536 COVIDARDS patients in the NorthCARDS dataset, there were 531 (34.6%) who had very low lung compliance (< 20 ml/cmH2O), 970 (63.2%) with low-normal compliance (20-50 ml/cmH2O), and 35 (2.2%) with high lung compliance (> 50 ml/cmH2O). The very low compliance group had double the median time to intubation compared to the low-normal group (107.3 h (IQR 25.8, 239.2) vs. 39.5 h (IQR 5.4, 91.6)). Overall, 68.8% (n = 1057) of the patients died during hospitalization. In comparison to non-COVIDARDS reports, there were less patients in the high compliance category (2.2% vs. 12%, compliance ≥ 50 mL/cmH20), and more patients with P/F ≤ 150 (59.8% vs. 45.6%). There is a statistically significant correlation between compliance and P/F ratio. The Oxygenation Index is the highest in the very low compliance group (12.51, SD(6.15)), and lowest in high compliance group (8.78, SD(4.93)). CONCLUSIONS: The respiratory system compliance distribution of COVIDARDS is similar to non-COVIDARDS. In some patients, there may be a relation between time to intubation and duration of high levels of supplemental oxygen treatment on trajectory of lung compliance.


Subject(s)
COVID-19/physiopathology , Hypoxia/virology , Lung/physiopathology , Respiratory Distress Syndrome/virology , Adult , Aged , Aged, 80 and over , Biomechanical Phenomena , COVID-19/therapy , Case-Control Studies , Disease Progression , Female , Humans , Hypoxia/physiopathology , Hypoxia/therapy , Male , Middle Aged , Respiration, Artificial , Respiratory Distress Syndrome/physiopathology , Respiratory Distress Syndrome/therapy , Respiratory Function Tests , Retrospective Studies , Treatment Outcome
17.
Sensors (Basel) ; 22(2)2022 Jan 13.
Article in English | MEDLINE | ID: covidwho-1634024

ABSTRACT

The present study was performed to investigate the validity of a wireless earbud-type inertial measurement unit (Ear-IMU) sensor used to estimate head angle during four workouts. In addition, relationships between head angle obtained from the Ear-IMU sensor and the angles of other joints determined with a 3D motion analysis system were investigated. The study population consisted of 20 active volunteers. The Ear-IMU sensor measured the head angle, while a 3D motion analysis system simultaneously measured the angles of the head, trunk, pelvis, hips, and knees during workouts. Comparison with the head angle measured using the 3D motion analysis system indicated that the validity of the Ear-IMU sensor was very strong or moderate in the sagittal and frontal planes. In addition, the trunk angle in the frontal plane showed a fair correlation with the head angle determined with the Ear-IMU sensor during a single-leg squat, reverse lunge, and standing hip abduction; the correlation was poor in the sagittal plane. Our results indicated that the Ear-IMU sensor can be used to directly estimate head motion and indirectly estimate trunk motion.


Subject(s)
Torso , Wearable Electronic Devices , Biomechanical Phenomena , Humans , Knee Joint , Pelvis
18.
J Mater Sci Mater Med ; 33(1): 8, 2022 Jan 04.
Article in English | MEDLINE | ID: covidwho-1602899

ABSTRACT

The collection capacity of common nasopharyngeal swabs and irregularities of medical personnel limit the accuracy of PCR testing. This study describes a newly designed 3D-printed swab that is combined with a 3D-printed cover to prevent the extraction of undesired nasal secretions. This swab improved the accuracy of PCR test results. The results of a series of experiments showed that, because of the mucus extraction effect, 3D-printed swabs can replace ordinary cotton swabs. The crisis of the worldwide medical supply shortage can be ameliorated to a certain extent by applying 3D printing technology.


Subject(s)
COVID-19 Nucleic Acid Testing/instrumentation , Specimen Handling/instrumentation , Biocompatible Materials , Biomechanical Phenomena , COVID-19/diagnosis , COVID-19/virology , Computer Simulation , Equipment Design , Finite Element Analysis , Humans , Materials Testing , Nasopharynx/virology , Printing, Three-Dimensional , Resins, Synthetic , Safety , Tensile Strength , Textiles
19.
Int J Mol Sci ; 23(1)2021 Dec 28.
Article in English | MEDLINE | ID: covidwho-1580696

ABSTRACT

The inhibition of key enzymes that may contain the viral replication of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) have assumed central importance in drug discovery projects. Nonstructural proteins (nsps) are essential for RNA capping and coronavirus replication since it protects the virus from host innate immune restriction. In particular, nonstructural protein 16 (nsp16) in complex with nsp10 is a Cap-0 binding enzyme. The heterodimer formed by nsp16-nsp10 methylates the 5'-end of virally encoded mRNAs to mimic cellular mRNAs and thus it is one of the enzymes that is a potential target for antiviral therapy. In this study, we have evaluated the mechanism of the 2'-O methylation of the viral mRNA cap using hybrid quantum mechanics/molecular mechanics (QM/MM) approach. It was found that the calculated free energy barriers obtained at M062X/6-31+G(d,p) is in agreement with experimental observations. Overall, we provide a detailed molecular analysis of the catalytic mechanism involving the 2'-O methylation of the viral mRNA cap and, as expected, the results demonstrate that the TS stabilization is critical for the catalysis.


Subject(s)
Methyltransferases/metabolism , RNA Caps/chemistry , RNA Caps/metabolism , SARS-CoV-2/enzymology , SARS-CoV-2/genetics , Viral Nonstructural Proteins/metabolism , Viral Regulatory and Accessory Proteins/metabolism , Biocatalysis , Biomechanical Phenomena , Methylation , Methyltransferases/chemistry , Molecular Dynamics Simulation , Quantum Theory , RNA Processing, Post-Transcriptional , Viral Nonstructural Proteins/chemistry , Viral Regulatory and Accessory Proteins/chemistry
20.
Annu Int Conf IEEE Eng Med Biol Soc ; 2021: 6818-6821, 2021 11.
Article in English | MEDLINE | ID: covidwho-1566242

ABSTRACT

Running gait assessment for shoe type recommendation to avoid injury often takes place within commercial premises. That is not representative of a natural running environment and may influence normal/usual running characteristics. Typically, assessments are costly and performed by an untrained biomechanist or physiotherapist. Thus, use of a low-cost assessment of running gait to recommend shoe type is warranted. Indeed, the recent impact of COVID has heightened the need for a shift toward remote assessment in general due to social-distancing guidelines and restriction of movement to bespoke assessment facilities. Mymo is a Bluetooth-enabled, inertial measurement unit (IMU) wearable worn on the foot. The wearable transmits inertial data via a smartphone application to the Cloud, where algorithms work to recommend a running shoe based upon the users/runner's pronation and foot-strike location/pattern. Here, an additional algorithm is presented to quantify ground contact time and swing/flight time within the Mymo platform to further inform the assessment of a runner's gait. A large cohort of healthy adult and adolescents (n=203, 91M:112F) were recruited to run on a treadmill while wearing the Mymo wearable. Validity of the inertial-based algorithm to quantify ground contact time was established through manual labelling of reference standard ground truth video data, with a presented accuracy between 96.6-98.7% across the two classes with respect to each foot.Clinical Relevance-This establishes the validity of a ground contact and swing times for runner with a low-cost IoT wearable.


Subject(s)
COVID-19 , Running , Wearable Electronic Devices , Adolescent , Adult , Algorithms , Biomechanical Phenomena , Humans , SARS-CoV-2
SELECTION OF CITATIONS
SEARCH DETAIL